Minakshi, Sharma, and Rani: Effect of filter media and hydraulic retention time on the performance of vertical constructed wetland system treating dairy farm wastewater

Abstract

This study deals with the dairy wastewater treatment using laboratory scale vertical flow (VF) constructed wetlands with the Canna indica plantation over wetland beds due to phytoremediation capabilities. Three laboratory scale VF CWs (CW-A, CW-B and CW-C) each with an area of 0.135 m2 filled with gravel (CW-A: 20 mm; CW-B:10 mm gravel) and sand (CW-C) receiving 0.04 m3 d−1 dairy wastewater were operated for the wastewater purification. Each unit was operated at three hydraulic retention times (HRTs) i.e. 12 h, 24 h and 48 h for assessing its effect on wastewater purification. Among all units, removal rates fluctuated as: total suspended solids (TSS): 64.2–74.5%; biochemical oxygen demand (BOD): 45.3–63.1%; ammonium nitrogen (NH4–N): 29.6–56.5% and phosphate phosphorous (PO4–P): 20.5 – 57.8% at different HRTs. Increase in HRT showed better removal of pollutants in all CWs. Moreover, maximum removal of pollutants excluding TSS and NH4-N was achieved in CW-B at 48 h HRT. CW-B with similar HRT provided maximum removal of PO4-P (57.8%), BOD (63.1%) and chemical oxygen demand (COD): 67.4%. Increase in the size of filter media, from sand (0.25 mm) to 20 mm gravel resulted in higher removal of NH4 -N from wastewater.

1. Introduction

Dairy farm practices release a huge volume of wastewater into the surrounding environment [1]. This wastewater is a mixture of animal urine, spilled milk, floor and utensil washings, traces of animal dung etc. It consists of small to medium strength of organic matter, phosphorous and nitrogen which is responsible for the problems of eutrophication in the receiving water bodies and degradation of soil quality as well [2]. In the past, many treatment techniques such as application of organic coagulants [3], advanced oxidation processes, membrane technology, anaerobic digestion [4], activated sludge process, trickling filters, rotating biological contractor, oxidation pond, UV disinfection, etc. have been tested for removing pollutants from dairy wastewater but only limited technologies could be successfully adopted. However long term use of these technologies was impaired due to high treatment cost, skilled labor, problem of sludge disposal, etc. Constructed Wetland (CW) technology is a convenient and eco-friendly alternative which is well suited for treating such kinds of wastewater [5]. Moreover, this technology has added advantages of; low treatment cost, better performance for removal of organic substances and nutrients like N, P along with ability to tolerate load fluctuations in influent [6].
Constructed wetlands (CWs) are engineered systems that have been designed and used to utilize the natural processes involving wetland vegetation, soils, and associated microbial assemblages to assist in wastewater treatment [7]. Among the different designs of CWs, Horizontal, Vertical and Hybrid systems are the most common and had shown effective results in terms of pollutant removal from wastewater [8]. Construction of a CW system, involves consideration of many design parameters such as influent quality, desired effluent quality, organic dosing rate, selection of appropriate filter material and macrophytes, hydraulic retention time (HRT), BOD/P/N ratio, bed depth, arrangement of beds (parallel or series) and surface partition at bed surfaces [9]. In VF CW system, filter media and plants play an important role in P removal [10]. These potent filter media such as sand and gravels have the capacity to bind phosphate and thus precipitate the phosphate content from wastewater. Along with this, plant such as Arundo donax absorb the readily available phosphate which are attached to the filter media surface [11].
The present study focusses on the removal of pollutants i.e. NH4-N, TSS, PO4-P, BOD and COD using laboratory scale vertical flow CW systems filled with different filter materials and operated at different HRTs for the treatment of dairy farm waste water. The CW system were planted with Cana indica owing to previous studies with similar plant, easy availability, price and aesthetic values [12].

2. Materials and Methods

2.1. Study Site and Construction of Vertical Flow CW Systems

The present study was conducted at Graphic Era University, Dehradun (30.3165° N, 78.0322° E), Uttarakhand, India. Laboratory scale CW systems were built using round shaped plastic container with a depth of 50 cm (surface area: 0.135 m2). Three such containers were labelled as CW-A, B, C filled with 20 mm gravel, 10 mm gravel and sand, respectively. On the surface of each CW Cana indica was planted. Canna indica plant has phytoremediating properties and can easily grow in wet and marshy regions. Arrangement of sampling was made at the bottom of each container using a water tap (Fig. 1).

2.2. Filter Materials

As per previous studies, different filter materials such as gravels of varied sizes, sand, etc. may be used in a CW unit [13]. Sand, being fine in size acts as the best filter material and treats wastewater using physical, biological and chemical processes [14] but is associated with problem of clogging. On the other hand, gravels too have its own advantages of excellent nitrification potential because of greater pore space for air availability and better adheration surface for microbial films which provides good mineralization of organic nitrogen and oxidation of ammonium ions [15]. This helps in maintaining aerobic conditions on the bed surfaces which supports the pollutant removal processes. Moreover, the gravel filled systems are less susceptible to clogging during their operation.
As the wastewater percolates slowly through the filter material, various physical, biological and chemical processes occur in combination resulting in the removal of pollutants from wastewater. Phosphorous gets attached to sand/gravel surface resulting in adsorption and precipitation processes in the CW unit [15]. These filter materials act like a natural home for variety of microbes such as Bacillus, Micrococcus, Pseudomonas etc. which contribute to organic matter degradation as well as nitrification and denitrification [16]. These filter materials serve as efficient units for removal of pollutants from wastewater (BOD, COD, NH4-N, PO4-P and fecal coliforms).

2.3. Hydraulic Retention Time (HRT)

HRT is the most easily changed operational variable in the design of CW system [17]. The performance of a Constructed Wetland system largely depends on the selected HRT because it reflects a contact period between wastewater and the wetland system [18].
Previous studies by DeBusk and Reddy [19] and Kadlec and Knight [20], recommended that longer the contact period of water with the filter material inside the wetland, more removal of pollutants occurs. In the past many studies were conducted at different HRTs (8 h to 20 d) (Table 1) However, most of these studies were focussed on the treatment of domestic wastewater. To the best of our knowledge, none of the study has been conducted for treatment of dairy farm wastewater at shorter HRTs.
Based on previous studies related to filter materials and HRT in CWs, this research work was designed to analyse the performance of laboratory scale vertical sub-surface flow Constructed Wetland systems operated with different filter material and HRTs and their combined effect on removal of organic and inorganic pollutants from dairy wastewater.

2.4. Experimental Design and Collection of Samples

Dairy wastewater samples were collected from dairy farm located nearby Graphic Era University, Dehradun Uttarakhand, India. In this study, different filter materials i.e. gravel of 10 mm and 20 mm sizes and sand were used in separate CW units (A, B and C). Canna indica plant was selected for surface plantation and was collected from a sewage drain located near Graphic Era University. Filter materials and the plants were brought to the laboratory and washed properly before starting the experiment. Plastic containers of depth 50 cm and diameter 41.5 cm each were taken for the experiment. 20 mm and 10 mm gravels were filled throughout the container A (CW-A) and container B (CW-B), respectively while container C (CW-C) was filled from top to bottom with washed sand (0.25 mm). Control systems for all the three CW systems were also considered for the study. The control CW systems had the same materials and other specifications as CW-A, CW-B and CW-C, but were operated at zero HRT unlike CW-A, CW-B and CW-C.
On the basis of retention time, flow rates, bed surface area and concentrations of organic matter and nitrogen, the decomposition constant coefficients (k) for wastewater treated in VF beds were calculated. First order equation form presented in (Eq. (1)), which uses kv rate and the HRT for VF beds:
(1)
Cout/Cin=exp.(-kA/q)
Here, q = hydraulic loading rate in m d−1 i.e. calculated as the ratio of flow rate (Q) in m3 d−1 and surface area (A) in m2 whereas kA is the decomposition constant in m d−1 [21].
Forty litres of dairy farm wastewater was dosed intermittently (batch feeding mode) everyday to each container. Dairy influent was analyzed for pH, ORP (oxidation reduction potential), EC (electrical conductivity), TDS (total dissolved solids), TSS (total suspended solids), salinity, DO (dissolved oxygen), temperature, BOD (biochemical oxygen demand), COD (chemical oxygen demand), NH4-N (ammonium-nitrogen), and PO4-P (phosphate phosphorous) before dosing to the CW systems. Treated samples from control beds and all the three systems were collected in 1 litre plastic bottles. These treated water samples were collected at specific HRTs (0 h, 12 h, 24 h and 48 h) through the knob at the base of each container after HRT of 12 h, 24 h and 48 h, respectively. The study was carried out for a period of three months (from March to May 2019).

2.5. Analytical Procedures

Regular samples were collected from the outlets of all the three containers after HRT of 0 h, 12 h, 24 h and 48 h, respectively and stored in refrigerator for analysis. Samples from the control beds of all the three CW systems were collected at zero h HRT i.e. no HRT was set in these beds. All the untreated and treated water samples were analysed in laboratory as per the guidelines of standard methods for examination of water and wastewater [22] and Hach Manual. pH, ORP, EC, TDS, salinity and temperature were analyzed during the study period by using multiparameter system (Hach SensION+ MM 150). DO was measured using DO meter (Hach SensION). Similarly, other parameters were measured using methods such as TSS (colorimetric method), BOD (3-d incubation method), COD (reactor digestion method), NH4-N (salicylate method) and PO4-P (molybdovanadate method).

2.6. Determination of Removal Rate

The efficiency of the vertical sub-surface constructed wetland system for removal of pollutants was calculated in terms of removal rate using the following equation [5].
(2)
Removalrate(%)=(Ci-Co)*100/CiCi=Influentconcentration(mgL-1);Co=Effluentconcentration(mgL-1)
  • Ci = Influent concentration (mg L−1);

  • Co = Effluent concentration (mg L−1)

3. Results and Discussion

3.1. pH, DO, NO3-N and NH4-N

Average pH in the influent was recorded as 7.2 ± 0.4 which changed between 7.23 ± 0.2 in control, 7.3 ± 0.3 to 7.5 ± 0.3 in CW-A, 7.2 ± 0.4 to 7.5 ± 0.2 in CW-B and 7.4 ± 0.3 to 7.7 ± 0.2 in CW-C unit (Table S1). Although no significant change in pH was observed at different HRTs yet maximum pH change was observed at 48 h HRT in all CW systems. Average DO concentration in the influent was found to be 4.3 ± 2.0 mg L−1. The control bed of CW-A showed a fluctuation of 2.9 to 4.9 mg L−1 during the study period while in CW-B control bed, it ranged between 3.0 to 5.0 mg L−1. The control bed of CW-C showed minimum and maximum DO values of 2.9 and 4.9 mg L−1, respectively. In the treated water, DO was recorded in the range of 4.9 ± 0.35 to 5.8 ± 0.8 mg L−1 among all CW systems. CW B (10 mm gravel filled unit) showed 4.9 ± 0.35, 5.0 ± 0.6 and 5.2 ± 0.2 mg L−1 average DO concentrations at HRTs 0, 12, 24 and 48 h, respectively (Fig. 2). A slightly higher DO increase (5.1 ± 0.5 to 5.8 ± 0.8 mg L−1) was observed in CW-A (20 mm gravel filled) and CW-C i.e. sand filled unit (5.1 ± 0.6 to 5.4 ± 0.7 mg L−1). The percent DO increase at outlets w.r.t influent DO concentration was observed as 34.9 and 25.6% in CW-A and CW-C respectively at 24 h HRT and 20.9% in CW-B at 48 h HRT. Maximum DO increase of 5.8 mg L−1 was recorded in 20 mm gravel filled system at an HRT of 24 h.
Nitrification is a key characteristic of vertical flow systems [23]. The influent showed an average NO3-N concentration of 1.5 ± 0.8 mg L−1. Effluents of control and all the CW systems showed higher NO3-N concentrations; 2.1 ± 0.5 – 3.0 ± 0.3 mg L−1 in CW-A, 1.8 ± 0.3 – 3.7 ± 0.4 mg L−1 in CW-B and 1.7±0.3 – 1.98 ± 0.5 mg L−1 in CW-C. In all the CW systems NO3-N concentration showed an increase (42.9% in CW-A, 32.1% in CW-B and 13.1% in CW-C) when HRT was increased from 12 h to 24 h however, when HRT was further extended to 48 h, the NO3-N concentration showed a decrease in effluent (Table S1). This might be due to denitrification process which occurs at longer HRTs. It has also been reported that at longer HRT a well-developed microbial community in CWs gets suitable contact time to remove pollutants [24, 25]. In a study by Toet et al. [25] positive nitrogen removal was observed in CWs with an HRT of 0.8 d in comparison to 0.3 day HRT. Further longer HRT led to anoxic conditions in the bed which facilitates denitrification process [26]. In addition, the effect of HRT may differ between CWs depending on the dominant plant species, temperature, type of wastewater and feeding mode as those factors can affect the hydraulic efficiency of wetlands [24, 25].
Maximum nitrate concentration (3.0 mg L−1) i.e. 100% increase w.r.t influent concentration was observed in CW-A (20 mm gravel filled) at a HRT of 24 h. while minimum NO3-N concentration of 1.7 mg L−1 was observed in CW-C (sand filled) at an HRT of 48 h.
Average concentration of NH4-N in the dairy influent was recorded as 48.0 ± 3.5 mg L−1. Average NH4-N concentrations at CW-A outlet (20 mm gravel filled unit) was found as 27 ± 3.5 mg L−1 (12 h), 21 ± 4.1 mg L−1(24 h) and 20.9 ± 3.2 mg L−1 (48 h HRT) whereas at CW-B outlet, average NH4-N concentration was recorded as 29.1 ± 3.7, 24.3 ± 4.0 and 25 ± 2.5 mg L−1 at HRTs 12, 24 and 48 h (Table S1). The NH4-N concentrations in the control beds of CW-A, CW-B and CW-C fluctuated between 29.1 to 38.1 mg L−1, 33.1 to 41.4 mg L−1 and 39.6 to 45.2 mg L−1, respectively (Fig. 4). During its retention insided the wetland bed, water undergoes certain physical, chemical and biological processes which leads to removal of toxic pollutants like ammonium, nitrogen, suspended solids and phosphate. The major processes involved in removal of ammonium nitrogen in a CW are nitrification-denitrification [27]. Nitrogen removal in constructed wetland depends upon environmental parameters (e.g. pH, oxygen, temperature etc.), operating conditions (hydraulic and pollutant loading, detention time, influent feed mode, recirculation, organic carbon addition etc.) and presence of microorganisms [24]. Among these parameters HRT plays an important role as it affects the contact duration between microbes and pollutants [28]. In this study, CW-A unit provided 43.8% removal of NH4-N at 12 h HRT which was subsequently increased to 56.3 and 56.5% at 24 h and 48 h HRTs. In CW-B unit (10 mm gravel filled), average removal percentage was recorded as 39.4% at 12 h HRT, further showed an increase of nearly 10% on extending HRT to 24 h. However no further increased was observed in NH4-N removal when HRT was taken to 48 h (Fig. 5). More or less similar trend was observed in sand filled unit, CW-C which provided 29.6% NH4-N removal at 12 h HRT. This was further increased to 43.1% and 43.8% at 24 h and 48 h HRTs, respectively. In a similar study [29], with field scale VF CW system (20 mm gravels), the removal of NH4-N was more (75% removal in 24 h HRT) as compared to lab-scale VF CW system filled with 20 mm gravels (56.3% in 24 h). Our results are not in an agreement with a previous study carried out by Akratos and Tsihrintzis [30] in which the overall removal of NH4-N was achieved as 74.9 and 87.5% at HRTs of 14 and 20 d, respectively. The differences in result may be due to variation in HRTs of both studies which were 0–48 h in our study against 14–20 d in the compared study.

3.2. TSS and PO4-P

Total suspended solids (TSS) are the substances of size > 2 microns and are present in the form of inorganic materials, though dust, bacteria, algae etc. may also contribute to total solid concentration in water [31, 32]. The average concentration of suspended solids in dairy influent was recorded as 628.0 ± 53.0 mg L−1 (Table S1). The control beds of CW-A and CW-B showed fluctuations in TSS concentration from 288.0 to 515.0 mg L−1 and 365.0 to 615.0 mg L−1, respectively whereas in sand control beds, fluctuation of 250.0 to 500.0 mg L−1 was recorded (Fig. 2). Gravel (20 mm) in CW-A showed a removal of 64.2% of TSS at 12 h HRT which showed more or less similar removal rate when HRT was increased to to 24 h HRT. Likewise, no further increase in removal rate was observed at 48 h HRT (Fig. 6). Gravel (10 mm) in CW-B unit also showed silimar pattern with 67.9% removal at 12 h and 68.4% at 24 h HRT. No further increase in the removal rate was seen at 48 h HRT. Sand showed maximum removal of suspended solids (73.1–74.5%) at all HRTs in CW-C because sand acts as a fine filter medium and is capable to remove small to large size suspended particles from the wastewater (Fig. 5). Vymazal [33] in one of his study recorded 75% removal of suspended solids using gravel media as substrate. Another studies suggested that TSS removal is mainly a physical process and is also affected by retention time [3436] but in our study, HRT did not produce a significant change in the TSS removal capacity of all three CW units. However, substrates play a very vital role in TSS removal as recorded in the study conducted by Manios et al. [37] in which removal percentage of TSS was found to be 85 and 90% in gravel and sand respectively. In our study, sand filter with 48 h HRT arrangement was found to be most suitable for achieving maximum (74.5%) TSS removal from the waste water.
Phosphorous in wetlands occurs as phosphate in organic and inorganic compounds. In a wetland system, P removal occurs by adsorption and precipitation mechanisms. The P present in the wastewater usually gets bind to the filter substrates of the CW beds as a result of adsorption and precipitation reactions by combining with the Ca, Al and Fe present in the gravel or sand substrates [31]. Thus the ability of VF CW beds to reduce P is dependent on the contents of these minerals in the filter media. Other factors like plant uptake and biological reactions do not play major role in P removal [31]. Thus, filter media has an important role in removing phosphorus from wastewater. PO4-P in influent has an average concentration of 41.0 ± 4.7 mg L−1. In the control system of CW-A and CW-B, the PO4-P concentration was found to be fluctuating between 35.5 to 41.5 and 31.2 to 41.8 mg L−1, respectively while in sand (CW-C) control bed, it was recorded to range from 30.8 to 40.1 mg L−1 (Fig. 3). Average PO4-P concentration at the outlet of CW-A was recorded as; 32.6 ± 4.8 mg L−1 at 12 h, 26.4 ± 3.6 mg L−1 at 24 h and 22.8 ± 2.9 mg L−1 at 48 h HRT (Table S1). In CW-A (20 mm gravel filled unit), removal rate of PO4-P was observed as 20.5% at 12 h HRT. An increment of 15.1% was recorded at 24 HRT resulting in 36.6% removal. On further increasing HRT to 48 h, PO4-P removal rate was increased upto 44.4%. In CW-B (10 mm gravel filled unit), average PO4-P concentration in treated water was observed as; 27.3 ± 4.4, 19.4 ± 3.6 and 17.3 ± 3.3 mg L−1 at 12, 24 and 48 h HRTs, respectively. The average removal rate was recorded as 33.4% at 12 h HRT; 52.7% at 24 h
HRT and further an increase of 5.1% at 48 h (Fig. 7). In CW-C (Sand filled unit), PO4-P removal rates was recorded as 25.9, 44.1 and 46.1% at 12 h, 24 h and 48 h HRTs, respectively (Fig. 7). Among all the three CW units, CW-B (10 mm gravel filled unit) showed maximum removal of PO4-P at 48 h HRT. Phosphorous removal mainly takes place by absorption by plants and sorption processes on the media used, and this phosphorous can be stored in the accumulated sediments [32]. Seo et al. [32], in his study, explained that P may remain bound to the media components as a result of precipitation and adsorption reactions with ions (Ca, Fe or Al) present in sand or gravels. The particle size of substrates which are suitable for P removal may vary significantly.
Our results showed a higher PO4-P removal as compared to a study conducted by Arias et al. [35] in which the maximum removal (45.6%) of PO4-P was achieved at HRT of 7 d. In another study conducted by Stearman et al. [36], maximum PO4-P removal was recorded as 10% at 0.7 day HRT.

3.3. BOD3 and COD

Biochemical Oxygen Demand (BOD) determines the amount of oxygen required by the biological organisms to degrade organic pollutants. It is a pollution indicating parameter. The average BOD3 value found in the dairy influent was 815.0 ± 33 mg L−1 (Table S1). The BOD value in control beds of CW-A and CW-B fluctuated from 402.0 to 558.0 and 400.0 to 510.0 mg L−1, respectively (Fig. 3) while the average BOD values were observed as 466.4 and 475.4 mg L−1 in CW-A and CW-B, respectively. CW-C control bed showed BOD range between 410.0 to 550.0 mg L−1 with an average value of 498.1 mg L−1.
The average BOD3 decrease at outlet amongst the three setup was most prominent in CW-B outlet (10 mm gravel filled). The BOD3 removal rate was observed as: 46.3, 60.9 and 62% in CW-A at 12 h, 24 h and 48 h HRTs respectively (Fig. S1). In CW-B (10 mm), the removal rate was recorded as 48.1 and 62.2% at 12 h and 24 h HRTs, respectively while no further change was observed at 48 h HRT (Fig. S1). In CW-C, the BOD3 removal rate was found to be 45.2, 57.1 and 58.5% at 12 h, 24 h and 48 h HRTs, respectively. Using a similar setup comprising of a 2-stage SSVF CW and a SSHF CW, Job [38] obtained BOD5 removal rate of approximately 65%. The BOD3 removal rate in our study showed an increase in all CW units (14.6 % in CW-A, 14.1 % in CW-B and 11.8% in CW-C) when HRT was increased from 12 to 24 h.
Chemical Oxygen Demand (COD) indirectly measures the amount of organic compounds in wastewater similar to BOD. It is also another pollution indicating parameter like BOD. During the study period, average concentration of COD recorded in dairy influent was 1,230.0 ± 48 mg L−1 (Table S1). The average concentration of COD was found to be decreased by 56.5% at 12 h, 64.6% at 24 h and 64.9% at 48 h HRT in CW-A. An increase of approximately 8% was observed in COD removal rate when HRT was increased from 12 h to 48 h in CW-A unit. In CW-B (10 mm gravel) removal was observed as 58.1, 66.5 and 67.4% at HRTs 12, 24 and 48 h. In CW-C, the percent removal was minimum among all the three filter materials and was recorded as 54.6, 62.3 and 63.0% at 12 h, 24 h and 48 h HRT, respectively. Plant activities have essential role in organic matter degradation [39, 40]. This occurs due to increase in plant biomass, leading to high amount of microbial development among the roots. Thus microbial degradation as well as biofilm formation is favoured leading to decrease in organic matter content of the wastewater.
From Table S1, it can be observed that maximum degradation of organic substances occurred in CW-B (10 mm gravel filled) at 24 h HRT. In a similar study [41] removal efficiency and removal of COD in gravel filled CW units were found in the range of 32.9 – 50.4% and 7.4 – 20.6 g m−2 d−1 in VFCW, respectively in 4.9, 2.4 and 1.2 d of HRT. A study conducted by Abed [42] stated that hydraulic retention time (HRT) of 24 h is enough for removal of pollutants from wastewater by the activities of filter media as well as plants.

4. Conclusions

The constructed wetland involves diverse processes (physical, chemical & biological) for removal of pollutants. Further, optimal operating parameters (i.e., water depth, hydraulic retention time and pollutant load) and wetland design also influence treatment performance of CW. The major findings of study are summarized as follows:
  • No significant change in pH was observed with variation in HRT.

  • The study showed higher removal of NH4-N and BOD3 with 48 h HRT in comparison to 12 h and 24 h HRTs. Removal rates of NH4-N and BOD3 were higher in gravel filled units compared to sand. The gravel has more porosity and provides more surface area for attachment of microbial community hence results in more pollutant removal.

  • Sand filled CW unit showed 10% higher removal of TSS compared to gravel filled units. Results indicate that change in HRT has least effect on TSS removal rate in all CW units.

  • Maximum DO increase of 5.8 mg L−1 was recorded in 20 mm gravel filled system at an HRT of 24 h. Results showed that change in HRT did not influence DO however change in DO was affected due to filter media size.

  • The maximum PO4-P removal (57.8%) was achieved by 10 mm gravel filled unit at 48 h HRT. For better PO4-P removal synthetic and industrial products with high phosphorus sorption capacity and hydraulic conductivity can be explored as alternative substrates in CWs in case of poor absorptive media.

  • During the study, change in removal rate of pollutants (NH4-N, BOD3, COD) was significantly higher (12.2–18.6%) when HRT was changed from 12 h to 24 h. A slight increase (< 3%) in the removal rate of pollutants was observed when HRT was increased from 24 h to 48 h. However this trend was not observed in case of TSS removal.

The study showed good removal of pollutants in all filter materials, however further study is recommended to validate findings on real-scale CW systems. We recommend assessment of planted vegetation for phytoremediation potential and biofilm formation on filter media in future studies for better understanding on pollutant removal mechanisms in CW.

Supplementary Information

Acknowledgements

Our sincere gratitude towards DBT, Ministry of Science and Technology, Government of India for supporting this work (Project No. BT/PR7545/BCE/8/999/2013). We are also thankful to Graphic Era Deemed to be University for providing necessary infrastructure for carrying out research work. Authors are thankful to Ms. Ankita Lal for manuscript proofreading.
This study was funded by DBT, Government of India through sanctioned research project (BT/PR7545/BCE/8/999/2013) to carry out research work. Partial funds and necessary infrastructure were provided by Graphic Era Deemed to be University for this work.

Notes

Author Contributions

D.M (Ph.D student) conducted all the experiments and wrote the manuscript. P.K.S (Professor) revised the manuscript. A.R (Associate Professor) wrote and revised the manuscript.

References

1. Britz TJ, Van Schalkwyk C, Hung Y. Treatment of dairy processing Wastewater. Wang LK, Hung Y-Tse, Lo HH, Yapijakis C, editorsWaste Treatment on the food processing Industry. 1st edCRC Press; Boca Raton, FL, USA: 2006. p. 1–28.


2. Feng C, Sugiura N, Shimada S, Maekawa T. Development of a high performance electrochemical wastewater treatment system. J Hazard Mat. 2003;103(1–2)65–78.
crossref

3. Tetteh EK, Rathilal S. Application of Organic Coagulants in Water and Wastewater Treatment. Organic Polymers, Arpit Sand and Elsayed Zaki. IntechOpen; 2019. p. 1–20.


4. Tetteh EK, Rathilal S, Chetty M, Armah EK, Asante-Sackey D. Treatment of Water and Wastewater for Reuse and Energy Generation-Emerging Technologies in Water and Wastewater Treatment. IntechOpen; 2019. p. 1–23.


5. Kato K, Inoue T, Ietsugu H, et al. Performance of six multi-stage hybrid wetland systems for treating high-content wastewater in the cold climate of Hokkaido, Japan. Ecol Eng. 2013;51:256–263.
crossref

6. Lei S, Bao-zehn W, Xiang-dong C, et al. Performance of subsurface-flow Constructed wetland in Southern China. J Environ Sci. 2004;16(3)476–481.


7. Vymazal J. Horizontal sub-surface flow and hybrid constructed wetlands systems for wastewater treatment. Ecol Eng. 2005;25(5)478–490.
crossref

8. Rousseau DP, Vanrolleghem PA, De Pauw N. Model-based design of horizontal subsurface flow constructed treatment wetlands: a review. Water Res. 2004;38(6)1484–1493.
crossref

9. Sharma PK, Takashi I, Kato K, Ietsugu H, Tomita K, Nagasawa T. Effects of load fluctuations on treatment potential of a hybrid sub-surface flow constructed wetland treating milking parlor waste water. Ecol Eng. 2013;57:216–225.
crossref

10. Babatunde AO, Zhao YQ. Phosphorus removal in laboratory-scale unvegetated vertical subsurface flow constructed wetland systems using alum sludge as main substrate. Water Sci Technol. 2009;60(2)483–489.
crossref

11. Sharma PK, Minakshi D, Rani A, Malaviya P. Treatment efficiency of vertical flow constructed wetland systems operated under different recirculation rates. Ecol Eng. 2018;120:474–480.
crossref

12. Hasan MR, Rina C. Use of algae and aquatic macrophytes as feed in small-scale aquaculture: A review (No. 531). Food and Agriculture Organization of the United Nations (FAO); 2009.


13. Aljerf L. Advanced highly polluted rainwater treatment process. J Urban Environ Eng. 2018;12(1)50–58.
crossref

14. Hellström D, Jonsson L. Evaluation of small on-site wastewater treatment systems. Manag Environ Qual. 2006;17(6)728–739.
crossref

15. Priya SG, Brighu U. Comparison of Different Types of Media for Nutrient Removal Efficiency in Vertical Upflow Constructed Wetlands. Int J Environ Eng Mgt. 2013;4(5)405–416.


16. Grant WD, Long PE. Environmental microbiology. 1st edBlackie and Son ltd; Glasgo, UK: 1981. p. 1–207.


17. Hunt BN. Determining the actual hydraulic retention time of a constructed wetland cell for comparison with the theoretical hydraulic retention time. [Thesis]. Athens: The University of Georgia; 2002.


18. Toet S, Van Logtestijn RS, Kampf R, Schreijer M, Verhoeven JT. The effect of hydraulic retention time on the removal of pollutants from sewage treatment plant effluent in a surface-flow wetland system. Wetlands. 2005;25(2)375–391.
crossref

19. DeBusk TA, Reddy KR. Wastewater treatment using floating aquatic macrophytes: contaminant removal processes and management strategies. Reddy KR, Smith WH, editorsAquatic plants for water treatment and resource recovery. Mangolia Publishing Inc; Orlando: FL: 1987.


20. Kadlec RH, Knight RL. Treatment wetlands. CRC Press/Lewis Publishers; Boca Raton, Florida: 1996.


21. Gajewska M, Skrzypiec K, Jóźwiakowski K, et al. Kinetics of pollutants removal in vertical and horizontal flow constructed wetlands in temperate climate. Sci Total Environ. 2020;718:137371.
crossref

22. APHA. Standard Methods for Examination of Water and Wastewater. American Public Health Association WWA; Washington, DC: 2005.


23. Butterworth E, Richards A, Jones M, Dotro G, Jefferson B. Assessing the potential for tertiary nitrification in sub-surface flow constructed wetlands. Environ Technol Reviews. 2016;5(1)68–77.
crossref

24. Saeed T, Sun G. A review on nitrogen and organics removal mechanisms in subsurface flow constructed wetlands: Dependency on environmental parameters, operating conditions and supporting media. J Environ Mgt. 2012;112:429–448.
crossref

25. Wu H, Zhang J, Ngo HH, et al. A review on the sustainability of constructed wetlands for wastewater treatment: Design and operation. Bioresour Technol. 2015;175:594–601.
crossref

26. Lee C, Fletcher T, Sun G. Nitrogen removal in constructed wetland systems. Eng Life Sci. 2009;9(1)11–22.
crossref

27. Estela JM, Cerdà V. Flow analysis techniques for phosphorus: an overview. Talanta. 2005;66(2)307–331.
crossref

28. Ye F, Li Y. Enhancement of nitrogen removal in towery hybrid constructed wetland to treat domestic wastewater for small rural communities. Ecol Eng. 2009;35(7)1043–1050.
crossref

29. Minakshi D, Sharma PK, Rani A, Malaviya P. Treatment of Dairy Farm Effluent Using Recirculating Constructed Wetland Units. Advances in Health and Environment Safety. Springer; Singapore: 2018. p. 57–66.
crossref

30. Akratos CS, Tsihrintzis VA. Effect of temperature, HRT, vegetation and porous media on removal efficiency of pilot-scale horizontal subsurface flow constructed wetlands. Ecol Eng. 2007;29(2)173–191.
crossref

31. Bunce JT, Ndam E, Ofiteru ID, Moore A, Graham DW. A review of phosphorus removal technologies and their applicability to small-scale domestic wastewater treatment systems. Front Environ Sci. 2018;6:8.
crossref

32. Seo DC, Cho JS, Lee HJ, Heo JS. Phosphorus retention capacity of filter media for estimating the longevity of constructed wetland. Water Res. 2005;39(11)2445–2457.
crossref

33. Vymazal J. Constructed wetlands for wastewater treatment: five decades of experience. Environ Sci Technol. 2010;45(1)61–69.
crossref

34. Green M, Safray I, Agami M. Constructed wetlands for river reclamation: experimental design, start-up and preliminary results. Biores Technol. 1996;55(2)157–162.
crossref

35. Arias CA, Del Bubba M, Brix H. Phosphorus removal by sands for use as media in subsurface flow constructed reed beds. Water Res. 2001;35(5)1159–1168.
crossref

36. Stearman GK, George DB, Hutchings LD. Removal of nitrogen, phosphorus and prodiamine from a container nursery by a subsurface flow constructed wetland. J Bioremed Biodegrad. 2012;S7:002.
crossref

37. Manios T, Stentiford EI, Millner P. Removal of total suspended solids from wastewater in constructed horizontal flow subsurface wetlands. J Environ Sci Health Part A. 2003;38(6)1073–1085.
crossref

38. Job GD. Treatment of medium strength industrial and agricultural effluents using reed bed treatment systems. [Thesis]. Birmingham: University of Birmingham; 1992.


39. Davies TH, Cottingham PD. The use of constructed wetlands for treating industrial effluent (textile dyes). Water Sci Technol. 1994;29(4)227–232.
crossref

40. Zachritz WH, Fuller JW. Performance of an artificial wetlands filter treating facultative lagoon effluent at Carville, Louisiana. Water Env Res. 1993;65(1)46–52.
crossref

41. Shutes RBE, Revitt DM, Mungur AS, Scholes LNL. The design of wetland systems for the treatment of urban run off. Water Sci Technol. 1997;35(5)19–25.
crossref

42. Abed SN. Effect of wastewater quality on the performance of constructed wetland in an arid region. [dissertation]. Birzeit: Birzeit University; 2012.


Fig. 1
Layout of CW-A, CW-B and CW-C for treatment of dairy farm wastewater.
/upload/thumbnails/eer-2020-436f1.gif
Fig. 2
Continuous DO and TSS concentrations in influent and effluent in control, CW-A, CW-B and CW-C during the study period.
/upload/thumbnails/eer-2020-436f2.gif
Fig. 3
Continuous PO4-P and BOD concentrations in influent and effluent in control, CW-A, CW-B and CW-C during the study period.
/upload/thumbnails/eer-2020-436f3.gif
Fig. 4
Continuous NH4-N concentrations in influent and effluent in control, CW-A, CW-B and CW-C during the study period.
/upload/thumbnails/eer-2020-436f4.gif
Fig. 5
NH4-N removal rates at different HRTs in VF CW. system.
/upload/thumbnails/eer-2020-436f5.gif
Fig. 6
TSS removal rates at different HRTs in VF CW system.
/upload/thumbnails/eer-2020-436f6.gif
Fig. 7
PO4-P removal rates at different HRTs in VF CW system.
/upload/thumbnails/eer-2020-436f7.gif
Table 1
Comparative Table Representing HRT Studies Carried Out by Various Researchers
Reference Design Type of wastewater HRT Removal rate (%)

BOD COD PO4-P TN NH4-N NO3-N TSS
Thalla et al. [47] VF CW Domestic wastewater 12 h 68 50 75 - 67.2 47.5 -
24 h 83 65 90 - 84.4 66.8 -

Zhu et al. [49] VFCW Domestic wastewater 48 h 85 77.9 89.9 - - 81.2

Raphael et al. [48] VFCW Raw gray water 3 d 35.4 56.7 65 92 - - 59.6

Stearman et al. [36] SSF CW Nursery irrigation runoff 0.7 d - - 10.0 70.8 - - -
1.2 d - - 7.7 71.8 - - -
1.9 - - −1.7 69.9 - - -

Arias et al. [35] SSF CW Domestic sewage 7 d - - 45.6 - - - -

Ghosh and Gopal [45] VF CW Dairy processing industry wastewater 1 d 30.4 30.8 26.1 35.4 81.0 40.8 80.2
2 d 69.6 72.2 55.6 80.5 92.9 85.8 90.2
3 d 82.2 85.0 63.3 84.9 99.4 95.9 95.6
4 d 93.9 97.1 92.7 94.6 92.7 98.6 98.8

Akratos and Tsihrintzis [30] HF CW Synthetic wastewater 6 d 87.9 88.7 29.3 44.8 19.1 - -
8 d 94.0 92.6 81.8 80.2 77.9 - -
14 d 91.2 92.8 90.3 78.9 74.9 - -
20 d 90.2 91.8 98.5 85.9 87.5 - -

Sirianuntapiboon et al. [46] VF (UF) CW Domestic wastewater 0.75 d 88.0 84.0 84.0 63.0 30.0 - 42.0
1.5 d 91.0 82.0 89.0 67.0 64.0 - 89.0
3 d 91.0 90.0 93.0 84.0 62.0 - 76.0

Toet et al. [18] SF CW STP effluent 0.3 d - 3.5 −4.5 14.3 16.9 21.2 -
0.8 d - 0.5 −10.1 24.3 29.2 29.8 -
2.3 d - 0.9 5.4 41.4 65.1 44.0 -
9.3 d - −12.8 1.6 63.1 87.0 85.6 -